PA6/3T: Polyamide 6/3T


Short Name
PA6/3T
Name
Polyamide 6/3T
Group
HTRTP - High-Temperature Resistant Thermoplastics
General Properties
Chemical Formula
Structural Formula

Properties

Glass Transition Temperature
145 to 153 °C
Melting Temperature
- °C
Melting Enthalpy
- J/g
Decomposition Temperature
460 to 470 °C
Young's Modulus
2000 MPa
Coefficient of Linear Thermal Expansion
80 *10¯6/K
Specific Heat Capacity
1.6 J/(g*K)
Thermal Conductivity
0.23 W/(m*K)
Density
1.12 g/cm³
Morphology
Amorphous thermoplastic
General properties
High mechanical stability. High chemical resistance. Good electrical insulation properties. Low processing shrinkage and tendency to wrap
Processing
Extrusion, injection molding, blow molding
Applications
Electrical engineering/electronics (switch housings, gear wheels, push buttons …). Mechanical and apparatus engineering (valve and control blocks, flow meter ...). Water management and filter technology

Internet Links

NETZSCH Measurements

Instrument
DSC 204 F1 Phoenix®
Sample Mass
12.73 mg
Isothermal Phase
3 min/3 min/5 min
Heating/Colling Rates
10 K/min
Crucible
Al, pierced
Atmosphere
N2 (50 ml/min)

Evaluation

Typically an amorphous polymer, PA6/3T exhibits a glass transition with a midpoint temperature of 142°C (1st heating, blue, midpoint) and 147°C (2nd heating, green, midpoint) which was overlapped by a relaxation peak in the 2nd heating. The step heights (Δcp) of this example were approx. 0.39 J/(g.K) (mean value of both heatings).